Procedure
To perform a migration of the configuration from a Netshield Appliance to another:
In this example its from a Netshield 300 to Netshield 500 Rev A
- Take a Backup.bkp(Configuration backup) of the Netshield 300.
- (Optional in this case) Take a Backup.bkp(Configuration backup) of the Netshield 500 Rev A. This is to be able to collect HWIdent values. Values below in Commands is from a Netshield 500 Rev A
- Upload the backup.bkp from Netshield 300 to Netshield 500 Rev A without activate/commit.
- Now apply the commands below.
- Activate and commit, Easiest way via serial console since you might loose ssh due to config change.
Commands:
set EthernetDevice G1 HWIdent=pci=04:00.0
set EthernetDevice G2 HWIdent=pci=04:00.1
set EthernetDevice G3 HWIdent=pci=04:00.2
set EthernetDevice G4 HWIdent=pci=04:00.3
set EthernetDevice G5 HWIdent=pci=06:00.0
set EthernetDevice G6 HWIdent=pci=06:00.1
set EthernetDevice S1 HWIdent=pci=05:00.0
set EthernetDevice S2 HWIdent=pci=05:00.1